Genesys - Access Control
| Manufacturer | Type | Comments |
| |
| ACT |
ACT 3000 Controller |
Door unlock, lock, normalize, pulse Open, door alarms
(held, forced), door status (open, unlocked, locked, held,
error), entry & exit events show user id number, controller
fault alarms, one connection to each 3000 controller
allowing 16 doors per connection, Genesys and ACTWinPro
can communicate with controllers together using 3000
controller firmware v1.25, IP connection, connection can
be made via serial or IP to the ACT 3000 controller (IP
preferred). |
| |
| Allen Bradley |
Allen Bradley PLC specific to special sites |
Hinged doors: Door Pop, Search mode, seal mode. No Alarms. Door unlocked shows open state, no unlocked and in frame
Sliding Doors: Door open, close, stop. No alarms. States shown are, open, closed and unknown (opening/closing)
Alarms: Activated and reset.
Communications fail alarm displayed
Contact Technical Sales for more detailed information. |
| |
| Borer |
Atrac Access Control |
Receive any predefined alarms the Borer system sends, IP
connection to the Borer Database. |
| |
| Castle |
ICASS Door Access |
For further information, please contact us. |
| |
| CCure |
Access Control using basic ASCII Protocol |
Door unlock, lock. door alarms (held, forced), door status
(open, unlocked, locked), serial connection to the CCure PC,
each alarm and action will need to be setup for each door in
the CCure software, CCUre and
Genesys can run together. |
| |
| Software House CCure |
800/8000 Serial Protocol with APC8 and i-star. CCure version 9.1 & 9.4 |
Door Unlock, Lock, Pulse open. Door Alarms: Held, Forced. Door Status: Open,
Unlocked, Locked. Badge picture displayed when invalid entry. IP Connection to CCure PC/Server.
CCure API license required on CCure server. Only v9.1 or v9.4 of CCure software can be used. |
| |
| Chubb |
Atlas, Mark 1 & 2 Locks |
Door control (unlock, lock, token enable, token disable,
lock enable, lock disable, ATP override, door timeout
override), door alarms (held, forced, fault, and all other
alarms), door status (open, unlocked, locked, insecure,
held, fault, token disable, lock disable, lock back, lock
mode), non lock related alarms are sent to controller device,
lost communication alarm, IP connection to Atlas Server,
Genesys and Atlas software need to run together. |
| |
| Chubb/ISM |
3R63 Locking Interface |
Door Control: Unlock, Lock, Audio Activation using 2 Ultimate Intercoms
per door. Door Held open alarms. MIO used with Chubb Locking Interface. |
| |
| Casi Rusco |
Picture Perfect |
Show alarms from alarm points and doors, IP connection to
Casi Rusco Server. |
| |
| DDS |
NTL-GTS Access Control |
Door control (unlock, lock, momentary unlock), door
alarms (held, forced, non lock related alarms),
door status (open, closed, forced, held), lost
communication to master alarm, configure all
controllers, configure doors and entry pin numbers, DDS software is
not required, serial connection to the DDS master controller. |
| |
| Hirsch |
Velocity |
Door control (unlock, lock, disable, enable), door alarms
(held, forced, error, card error), door status (forced, held),
lost communication alarm, IP connection to Hirsch
Velocity Server using XML, Genesys and Velocity software
need to run together. |
| |
| Integra |
Door Alarm |
Door unlock, lock, door alarms (held, forced), door status
(open, unlocked, locked), monitor transactions for invalid
tokens, IP connection to the Integra PC. |
| |
| Kantech |
Smartlink. V3.16 & v4.0 only |
Door control (unlock, lock, pulse open, enable, disable),
door alarms (held, forced, fault), door status (open,
unlocked, locked, held, forced, fault), lost communication
alarm, control of auxiliary relays, display alarm contact
inputs, IP or serial connection to Kantech Smartlink
(Entrapass global edition or version that runs smartlink),
Entrapass software and Genesys need to run together. |
| |
| Keri |
Keri Access Control PXL500 |
Door control (unlock, lock, pulse open), door alarms (held, forced),
door status (open, closed, held, forced), serial connection
to Keri PXL500 master, Keri software and Genesys cannot
communicate at the same time, Genesys Migration Server Technology cannot be applied.
|
| |
| Keri |
Keri Access Control PXL500 |
Door control (unlock, lock, pulse open), door alarms (held, forced),
door status (open, closed, held, forced), serial connection
to Keri PXL500 master, Keri software and Genesys cannot
communicate at the same time, Genesys Migration Server Technology cannot be applied. |
| |
| Keri |
NetXtreme (DNXT SQL) API |
Door control (unlock, lock, pulse open), door alarms (held, forced),
door status (open, closed, held, forced), serial connection
to master door controller. Available Winter 2009
|
| |
| Lintott |
Access Control Mitsubishi PLC |
Standard & sliding door, door control (unlock, lock,
interlock override), door alarms (held, forced), door status
(open, closed, opening, closing, mid position, alarm, electric
lock, mechanical lock, blot closed).
Vehicle doors, door control (vehicle entry open/close, vehicle
exit open/close, pedestrian open/close, stop, interlock
override, seq reset).
Alarms (held, forced).
Door status (open, closed locked,
closed unlocked, interlocked).
Serial connection to PLC.
|
| |
| Lintott |
Door Locking System (Mitsubishi) |
For further information please contact us.
|
| |
| Nedap |
Access Control |
For further information please contact us.
|
| |
| Plan |
640 Access Control |
Door control (unlock, lock, pulse open, normal), door
alarms (held, forced, fault), door status (open, unlocked,
locked), lost communication alarm, serial connection to Plan
software.
|
| |
| Westmont |
Locking System (Omron PLC) |
Lock/unlock doors.
Sliding doors, door control (open, half open, close
for vehicle gates).
Open/closed status of all doors, door
forced and fault alarms shown, serial connection to PLC.
For further information please contact us.
|
| |
|
|
|